Controlled pneumatic integrity testing

Know your dry riser still works, not just that it passed last year.

DP²luse™ uses controlled compressed air, pressure sensing and automated test control to check closed pipework between scheduled water tests, where permitted and appropriate. More checks, no repeated fill-and-drain.

Test cycleIllustrative
Illustrative pressure behaviourTwo pressure traces over time. The baseline test rises and holds steady. The current test rises similarly, then gradually decays. The difference is flagged: Change in behaviour → investigate.PRESSURETIME →Baseline testCurrent test
Change in behaviour → investigate

Illustrative pressure behaviour

  • Complements mandatory testing
  • Built-in safety protection
  • Manual or Smart configuration

The problem

A system can pass its test and still fail before the next one.

Scheduled testing is essential. But a result only describes the system on the day it was tested. Corrosion, joint and gasket deterioration, coupling movement and concealed leaks can develop in the months that follow, and a dry rising main is often only called on during an emergency.

Timeline: Test passed, then Normal service, then Deterioration, then Defect develops, then Next scheduled test, then Defect identified. The time between the passed test and the next scheduled test is an undetected period.
  1. Test passed↓ Undetected period
  2. Normal service
  3. Deterioration
  4. Defect develops
  5. Next scheduled test
  6. Defect identified
The question isn’t did the system pass its previous test? It’s can it perform its intended function today?
How defects can developSimplified. Actual failure mechanisms depend on pipe material, defect type, loading and environment.
  1. 01Initial defect
  2. 02Progressive deterioration
  3. 03Small leakage
  4. 04Increasing leakage / abnormal pressure behaviour
  5. 05Major leakage / failure

Why it matters in Singapore

Recent fires have shown what’s at stake.

In three residential fires in Singapore, firefighters found the dry rising main could not deliver water to the affected floors and had to haul hoses up the staircase from ground level. In two cases the riser had been tested and found in working order months earlier.

  1. July 2025

    Toa Payoh

    Reported issue
    Suspected underground pipe leak. The riser had last been tested in August 2024 and found in working condition.
    Engineering lesson
    Concealed sections matter.

    Source: CNA, “Toa Payoh fire: Faulty dry riser could be due to underground pipe leak, says town council”, 31 July 2025

  2. May 2026

    Joo Seng Road

    Reported issue
    Leakage at the riser base section. Water escaped at the base before reaching the upper floors.
    Engineering lesson
    The whole system, including the base, must stay watertight.

    Source: Lianhe Zaobao, “裕盛路火患 疑因干式消防立管底座破裂漏水拖慢灭火进度”, 5 May 2026

  3. July 2026

    Clementi

    Reported issue
    Possible coupling dislodgement. The riser had passed its annual pressure test in March 2026.
    Engineering lesson
    Couplings, joints and supports must stay secure.

    Source: CNA, “Firefighters hauled hose up 8 floors after dry rising main failed in fatal Clementi fire”, 3 August 2026

Integrity isn’t just the main pipe. It’s pipework, couplings, joints, supports, valves, gaskets and concealed sections, all of which affect whether water reaches the floor.

The DP²luse™ approach

Add checks between tests, using air instead of water.

DP²luse™ doesn’t replace the required high-pressure water test. It adds controlled pneumatic integrity checks during the service period, where permitted and appropriate, so you get more opportunities to see whether the system is still behaving as it should.

Conventional water test

5 steps
  1. 1Prepare
  2. 2Fill with water
  3. 3Test
  4. 4Drain
  5. 5Reinstate

DP²luse™ interim check

4 steps
  1. 1Boot up
  2. 2Pressurise with air
  3. 3Test
  4. 4Vent / Reset

The testing cycle

  1. 01

    One test, then a long wait

    In a conventional cycle, the mandatory water test is followed by an operating period with no further integrity information until the next scheduled test.

  2. 02

    Interim checks fill the gap

    DP²luse™ adds multiple interim pneumatic checks during the operating period, where permitted and appropriate.

  3. 03

    Mandatory testing still applies

    The next mandatory water test goes ahead as required. The interim checks add information between tests; they don’t stand in for them.

Comparison of testing cycles. Conventional cycle: a Mandatory water test, an operating period with no checks, then the Next mandatory water test. DP²luse™ enhanced cycle: the same mandatory tests, with 5 interim checks during the operating period.
Required high-pressure water testing
DP²luse™ interim pneumatic checks
a more reliable critical system

How it works

Pressure behaviour, not just pressure.

A single pass/fail reading can hide a slow change. DP²luse™ records how the system responds through each test cycle and compares it with previous results.

  1. 01

    Baseline

    After commissioning or the high-pressure test, the first DP²luse™ test records the system’s reference behaviour.

  2. 02

    Test

    Controlled air pressurises the closed system; sensors capture build-up, stabilisation and decay over time.

  3. 03

    Compare

    Each result is compared with earlier tests to spot changes.

  4. 04

    Act

    An abnormal change flags the system for human inspection and investigation.

What’s observed

  • Pressure build-up
  • Stabilisation
  • Pressure decay
  • Test duration
  • Change over time
  • Comparison with previous results
Try it: compare a test with its baseline
Illustrative. Not real test data.The current test closely follows the dashed baseline throughout the test.BUILD-UPSTABILISATIONDECAY WINDOWBaseline
Consistent with baseline
Illustrative. Not real test data.
Why test at a lower pressure?

The high-pressure water test establishes integrity at the specified test pressure. DP²luse™ is for interim monitoring after that regime, so its value comes from tracking whether behaviour stays consistent over time, not from matching the water-test pressure.

Why test at a lower pressure?
High-pressure water testDP²luse™ interim pneumatic test
Higher-pressure water-based testingControlled lower-pressure pneumatic testing
Establishes / verifies system integrity at the applicable test pressureMonitors pressure behaviour during interim checks
Conducted where required by applicable requirementsIntended to complement established testing regimes
Scheduled / periodicAdditional checks between scheduled tests, where permitted
Water-basedPneumatic

Safety and moisture protection

Engineered to fail safe.

  • Pressure relief valve

    Mechanical relief vents excess air automatically.

    Set at 8 bar · 114 psi

  • Compressor protection

    Built-in thermal and overpressure cut-out.

  • Automatic abort

    On a rapid pressure rise or sudden drop, the system aborts, stops the air supply, vents and returns to a safe state.

  • Water and moisture management

    A non-return valve, an auto-drain solenoid before and after each cycle, and air filtration keep water away from the equipment.

  • Emergency stop

    Manual E-stop for immediate shutdown.

  • Maintenance isolation

    A dedicated isolation ball valve lets the unit be isolated while the pipework stays operational.

    ½-inch isolation ball valve

Abort sequence
  1. Abnormal reading
  2. Abort
  3. Stop air
  4. Vent
  5. Safe state
DP²luse™ unit on a dry riserSchematic: a vertical dry riser pipe with landing valves. A DP²luse™ unit connects to the pipework through an isolation ball valve. The unit contains a compressor, pressure sensor, relief valve, non-return valve and auto-drain, with an emergency stop on the front.DRY RISER½″ ISOLATIONDP²luse™CompressorPressure sensorRelief valve · 8 barNon-return · auto-drainE-STOP
Schematic, not to scale. Product imagery to follow.

Systems

From a single riser to an entire estate.

Smart System

Centralised monitoring for portfolios.

Multiple units connect to a central platform, so the status of every system can be viewed from one place.

  • System health & status
  • Test status
  • Fault conditions
  • Power failure alerts
  • Network connectivity
  • Historical data for trend analysis

Best for Town Council estates, large residential developments, multi-building sites and property portfolios.

Discuss your site
Several DP²luse™ units across buildings connected to a central platform.Central platform

A scalable platform

Built to grow with your data.

  1. Level 1

    Manual testing

    1. Local unit
    2. User initiates
    3. Controlled test
    4. Local result
  2. Level 2

    Smart monitoring

    1. Many units
    2. Central platform
    3. Status, faults, test data
    4. Centralised maintenance
  3. Level 3

    Intelligent condition monitoring

    Roadmap

    Future pathway, growing as data accumulates.

    1. Historical data
    2. Trend analysis
    3. AI-assisted pattern recognition
    4. Early warning
    5. Predictive maintenance support
  • Test
  • Record
  • Monitor
  • Compare
  • Detect abnormality
  • Investigate
  • Rectify
  • Verify

AI-assisted analysis is decision support. It helps teams prioritise which systems to investigate; it does not decide on its own that a system has failed.

Applications

Starting with dry rising mains. Designed for more.

The same controlled pneumatic approach may suit other closed pipework that normally runs dry, or where introducing water is undesirable. Each application is evaluated individually.

Good fit where…

Assessed against

  • system design
  • operating pressure
  • pipe material
  • system volume
  • intended function
  • applicable standards
  • safety requirements
  • acceptance criteria
  • application-specific validation

Key advantages

Why DP²luse™.

  • More frequent integrity checks

    Additional pneumatic checks between scheduled water tests, where permitted and appropriate.

  • Reduced water use for interim testing

    Less need to repeatedly fill and drain suitable dry pipework for interim checks.

  • Lower operational burden

    Fewer preparation, filling, draining and reinstatement activities for interim checks.

  • Controlled, repeatable testing

    Automated pressure control and test sequencing for a more consistent process.

  • Integrated safety protection

    Manages overpressure, abnormal conditions, water ingress and emergency shutdown.

  • Scalable monitoring

    The Smart System lets multiple units be monitored from a central platform.

  • Data-driven maintenance

    Historical results give a basis for spotting changes in system behaviour.

  • Future predictive capability

    AI-assisted trend analysis as a pathway towards condition-based maintenance, as data accumulates.

Responsible application

DP²luse™ supports an established inspection, testing and maintenance programme. It does not replace statutory testing, inspection or certification. Where water-based testing is required by regulations, standards or project requirements, it still applies. Suitability for any application is assessed on system design, operating parameters, applicable standards, safety requirements and a validated test methodology.

White paper

Read the full white paper.

The engineering rationale, safety design, Manual and Smart configurations, and lessons from recent incidents, in 24 pages.

FAQ

Common questions.

Does DP²luse™ replace the annual water pressure test?
No. It adds interim pneumatic checks between scheduled water tests, where permitted and appropriate. Required water-based testing still applies.
Why test with air at a lower pressure?
It isn’t trying to repeat the high-pressure test. It monitors whether pressure behaviour stays consistent over time after the system has passed that test.
Will it put water or moisture into my equipment?
A non-return valve, automatic drain solenoid and air filter are built in to keep water away from the compressor and pneumatic parts.
What happens if something goes wrong during a test?
On a rapid rise or sudden drop in pressure, the unit aborts, stops the air supply, vents and returns to a safe state. There is also a relief valve (8 bar) and an emergency stop.
Can the riser still be used if the unit is being serviced?
Yes. A ½-inch isolation valve separates the unit from the pipework.
Manual or Smart: which do I need?
Manual suits single sites with local testing. Smart suits estates and portfolios that want central monitoring and historical data.
Does the AI decide whether my system has failed?
No. It flags changing trends to help teams prioritise investigation; people make the call.
Is it only for dry risers?
Dry rising mains are the first application. Other suitable closed, normally dry pipework may be considered case by case.

Contact

Talk to us about your site.

Tell us about your buildings and testing programme. We’ll explain how DP²luse™ could fit alongside it, and arrange a demonstration.